X144 e-FlowMeter
Quick Start Installation & Removal Instructions
X144 e-FlowMeter Included Hardware
patent pending
Complete
e-FlowMeter
Assembly
Parts List
1) X144 e-FlowMeter Assembly with
20 foot cable
2) Installation Kit containing:
a) Insertion Tool
b) Locking Collar with Thumb Set Screw
(a and b come assembled)
1
Locking
Collar
Thumb Set
Screw
Complete Installation Kit
2
a) Insertion Tool
Installation Kit Part Numbers:
Small (2.5” - 6” + 8” reduced Port): 208450-21K
Large (8” Full Port - 16”): 208450-20A
1
Step-By-Step X144 e-FlowMeter Installation Instructions
2
3
CLA-VAL
4
Isolation Valves
Step 2A:
Loosen Knurled Lock Nut on e-FlowMeter Assembly
Step 2B: Pull apart. Straighten Measurement Cylinder by
hand. Set aside Sensor/Head in safe location,
protecting sensor tip
Sensor/Head Assembly
Threaded Swivel Insert
Step 3A: Screw Locking Collar on straight threads. Insert
angled end of provided tool as shown, until it stops
Step 3B: Tighten Thumb Set Screw
Measurement
Cylinder
Thumb Set Screw
Locking Collar
Step 4: Apply Teflon® tape to NPT Threads
• Check threads on valve
• Use thread chasing tool (not supplied), if
necessary
b)
flow
Step 1: Take necessary safety precautions
• Isolate the control valve using main line
isolation valves
• Bleed pressure from valve before removing
body plug
• Remove an inlet body plug
NOTE: If both inlet body tappings are used for
the pilot system, consult factory for correct
modification instructions.
sensor
tip
Score Marks
Thumb Set Screw
tape not supplied
Page view 0
1 2 3 4

Summary of Contents

Page 1 - X144 e-FlowMeter

X144 e-FlowMeterQuick Start Installation & Removal Instructions X144 e-FlowMeter Included Hardwarepatent pendingCompletee-FlowMeter AssemblyParts

Page 2

X144 e-FlowMeterQuick Start Installation & Removal Instructions 7651098Step 5: Insert straightened Swivel Insert/MeasurementCylinder Assembly into

Page 3

X144 e-FlowMeterQuick Start Installation & Removal Instructions X144e-Flow Meterwhitebrown78CAUTION:Do not connect Pulse Output Circuit and 4-20mA

Page 4

X144 e-FlowMeterQuick Start Installation & Removal Instructions Before3Step 3: • Remove the e-FlowMeter Sensor/Head Assembly bypulling straight o

Comments to this Manuals